Test Code DIMER D-Dimer, Blood
Methodology
Automated Latex Enhanced Immunoassay
Performing Laboratory
Sky Lakes Medical Center-Coagulation
Specimen Requirements
Specimen must arrive in laboratory within 30 minutes of draw. Specimen Type: Whole blood Container/Tube: Light-blue top (3.2% sodium citrate) Specimen Volume: 90% full tube Collection Instructions: 1. When using butterfly, draw a discard tube prior to sodium citrate tube. 2. Invert several times to mix blood. 3. Do not centrifuge. 4. Tube must remain stoppered. 5. Avoid grossly hemolyzed, icteric, or lipemic specimen. Clotted or hemolyzed blood or insufficient specimen is not acceptable.
Specimen Transport Temperature
Refrigerate
Reference Values
230 ng/mL The negative predictive value for results 230 ng/mL is 100% to rule out deep vein thrombosis and pulmonary embolism. Other circumstances which lead to elevated D-dimer results are: old age, pregnancy, disseminated intravascular coagulation, coronary disease, thrombolytic treatment, cancer, liver disease, infection, inflammation, and hematomas. However, no clinical diagnosis should be based on the result of a D-dimer test alone. Clinical signs and other relevant information should be included.
Day(s) Test Set Up
Monday through Sunday Available STAT
Test Classification and CPT Coding
85379
Test Order Code
LAB313