Test Code HEXP Iohexol, Plasma
Reporting Name
Iohexol, PUseful For
Determining glomerular filtration rate in plasma specimens
Method Name
Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
Plasma HeparinSpecimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Green top (heparin)
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions: Centrifuge and aliquot plasma into a plastic vial.
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Plasma Heparin | Refrigerated (preferred) | 7 days | |
Frozen | 35 days | ||
Ambient | 7 days |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.Reference Values
Not applicable
Day(s) Performed
Monday through Friday
CPT Code Information
82542
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
HEXP | Iohexol, P | 93974-4 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
61713 | Iohexol, P | 93974-4 |
Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.Report Available
3 to 4 daysForms
If not ordering electronically, complete, print, and send a Renal Diagnostics Test Request (T830) with the specimen.