Test Code HHV6 Human Herpesvirus-6, Molecular Detection, PCR, Plasma
Reporting Name
HHV-6 PCR, PUseful For
As an adjunct in the rapid diagnosis of human herpesvirus-6 infection using plasma specimens
This test should not be used to screen asymptomatic patients.
Method Name
Real-Time Polymerase Chain Reaction (PCR)/DNA Probe Hybridization
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
Plasma EDTASpecimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Lavender top (EDTA)
Submission Container/Tube:
Preferred: Plastic vial
Acceptable: Screw-capped, sterile container
Specimen Volume: 1 mL
Collection Instructions: Centrifuge and aliquot plasma into plastic vial.
Specimen Minimum Volume
0.3 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Plasma EDTA | Refrigerated (preferred) | 7 days | |
Frozen | 7 days |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | OK |
Reference Values
Negative
Day(s) Performed
Monday through Saturday
CPT Code Information
87532
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
HHV6 | HHV-6 PCR, P | 29495-9 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
87532 | HHV-6 PCR, P | 29495-9 |
Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.Report Available
2 to 5 daysForms
If not ordering electronically, complete, print, and send a Microbiology Test Request (T244) with the specimen.